Adaptéry ADS

  • Power output – up to 12 W
  • Mounting – the adapter plugs directly into a mains socket
  • Regulated output voltage
  • Output voltage range from 3,1 V to 48 V
  • Input – adapter
  • Output – insulated twin-core cable
  • IP20 protection rating
  • Power output – up to 16 W
  • Mounting – the adapter plugs directly into a mains socket
  • Regulated output voltage
  • Output voltage range from 3,1 V to 48 V
  • Input – adapter
  • Output – insulated twin-core cable
  • IP20 protection rating

The converters are designed for general-purpose use to power electrical and electronic equipment with DC voltage in indoor, non-explosive environments. The output voltage can range from 3.1 V to 48 V. The adapters are characterized by their low weight and high efficiency.

The nominal output voltages and respective maximum output currents are listed in the table. The converter is protected against short-term output short circuits.

Table 1: Technical parameters

Input Voltage 195 - 255 V AC
Operating temperature -15 °C to +40 °C
Output short-circuit protection <1 min. (short-term)
Dielectric Strength 3000 V AC
Protection Rating IP20
Dimensions 55 × 41 × 45 mm
Weight 90 g
Electrical Safety EN 60950-1:2003
EMC EN 55011+A1:2002,
EN 61000-3-2:2002,
EN 61000-3-3:2000+A1:2003,
EN 61000-6-1:2003

Table 3: AC/DC Adapter Models 12ADS

Model Name Output Voltage Output Current Stability Ripple Noise
12ADS030/10.xx 3.1 V 1 A 2 % <70 mV <100 mV šš
12ADS050/10.xx 5 V 1 A 2 % <70 mV <100 mV šš
12ADS069/10.xx 6.9 V 1 A 2 % <70 mV <100 mV šš
12ADS090/10.xx 9 V 1 A 1 % <50 mV <100 mV šš
12ADS120/10.xx 12 V 1 A 1 % <50 mV <100 mV šš
12ADS138/08.xx 13.8 V 0.8 A 1 % <50 mV <100 mV šš
12ADS150/07.xx 15 V 0.7 A 1 % <60 mV <100 mV šš
12ADS180/06.xx 18 V 0.6 A 1 % <60 mV <100 mV šš
12ADS240/04.xx 24 V 0.4 A 1 % <60 mV <100 mV šš
12ADS276/03.xx 27.6 V 0.3 A 1 % <60 mV <100 mV šš
12ADS480/02.xx 48 V 0.25 A 1 % <70 mV <100 mV šš

.xx – the two-digit code specifies the type of connector on the output lead

Table 4: AC/DC Adapter Models 16ADS

Model Name Output Voltage Output Current Stability Ripple Noise
16ADS030/25.xx 3.1 V 2.5 A 2 % <130 mV <150 mV šš
16ADS050/25.xx 5.1 V 2.5 A 2 % <130 mV <150 mV šš
16ADS060/25.xx 6 V 2.5 A 2 % <120 mV <150 mV šš
16ADS069/14.xx 6.9 V 1.4 A 2 % <120 mV <150 mV šš
16ADS090/14.xx 9 V 1.4 A 1 % <120 mV <150 mV šš
16ADS120/14.xx 12 V 1.4 A 1 % <120 mV <150 mV šš
16ADS138/12.xx 13.8 V 1.2 A 1 % <100 mV <100 mV šš
16ADS150/11.xx 15 V 1.1 A 1 % <100 mV <100 mV šš
16ADS180/09.xx 18 V 0.9 A 1 % <80 mV <100 mV šš
16ADS240/07.xx 24 V 0.7 A 1 % <80 mV <100 mV šš
16ADS276/06.xx 27.6 V 0.6 A 1 % <80 mV <100 mV šš
16ADS480/03.xx 48 V 0.3 A 1 % <120 mV <150 mV šš

.xx – the two-digit code specifies the type of connector on the output lead

Output connector configurations:

Option .00 – without connector
The output lead length is 1.5 m.

Option .02 – autokonektor
The output lead length is 5 m.

Option .04
The output lead length is 1.5 m.

Option .05
The output lead length is 1.5 m.

Option .06
The output lead length is 1.5 m.

Option .07
The output lead length is 1.5 m.

Use of car connector .02: The use of a car connector, for example with the 12ADS series 13.8 V power supplies, allows for maintaining batteries in a charged state directly in the vehicle via the cigarette lighter socket or a dedicated connector provided for this purpose. This is particularly advantageous for emergency vehicles, such as fire trucks, which must be ready for immediate deployment at all times. During parking, starter batteries lose capacity due to self-discharge, as well as the effects of low temperatures in winter.